Thermo King Alarm Code (Cover For CSR Model)

Thermo King Alarm Code (Cover For CSR Model)
Read Term And Condition Before Use This Application !!!
Alarm No Alarm Description
00 Supply Air Sensor Open Circuit (Check Alarm)
01 Supply Air Sensor Short Circuit (Check Alarm)
02 Return Air Sensor Open Circuit (Check Alarm)
03 Return Air Sensor Short Circuit (Check Alarm)
04 Evaporator Coil Sensor Open Circuit (Check Alarm)
05 Evaporator Coil Sensor Short Circuit (Check Alarm)
06 R-134 Compressor Current Too High (Check Alarm)
07 R-134 Compressor Current Too Low (Check Alarm)
10 Heater Current Too High (Check Alarm)
11 Heater Current Too Low (Check Alarm)
12 Evaporator Fan High Speed Current Too High
13 Evaporator Fan High Speed Current Too Low
14 Evaporator Fan Low Speed Current Too High (Check Alarm)
15 Evaporator Fan Low Speed Current Too Low (Check Alarm)
16 Condenser Fan Current Too High (Check Alarm)
17 Condenser Fan Current Too Low (Check Alarm)
18 Power Supply Phase Error (Log Alarm)
19 Temperature Too Far from Setpoint (Check Alarm)
20 Defrost Time Too Long (Check Alarm)
22 Capacity Test 1 Error (Check Alarm)
23 Capacity Test 2 Error (Check Alarm)
24 Capacity Test 3 Error (Check Alarm)
25 Evaporator Temperature Test Error (Check Alarm)
27 Heat Capacity Test Error (Check Alarm)
28 Stepper Motor Valve Error
29 Liquid Injection Valve Error (Pretrip) (Check Alarm)
30 Bypass (Warm Gas) Valve Error (Pretrip) (Check Alarm)
31 Low Pressure Cutout Error (Check Alarm)
32 Condenser Temperature Sensor Open Circuit (Check Alarm)
33 Condenser Temperature Sensor Short Circuit (Check Alarm)
34 Ambient Air Sensor Open Circuit (Check Alarm)
35 Ambient Air Sensor Short Circuit (Check Alarm)
36 Total Current Too High (Log Alarm)
37 Total Current Too Low (Log Alarm)
41 Supply Air Temperature Too High (Check Alarm)
42 Supply Air Temperature Too Low (Check Alarm
43 Return Air Temperature Too High (Check Alarm)
45 Evaporator Coil Temperature Too High (Check Alarm)
46 46 Evaporator Coil Temperature Too Low (Check Alarm)
52 Probe Error (Check Alarm)
53 High Pressure Cutout Switch Off Error
54 High Pressure Cutout Switch On Error
56 Compressor Temperature Too High (Shutdown Alarm)
57 AFAM Control Module or Motor Error (Check Alarm)
58 Phase Sensor Error (Check Alarm)
59 Delta Current Error (Log Alarm)
60 Humidity Sensor Error
68 AFAM Gas Analyzer Error (Check Alarm)
97 Compressor Sensor Open Circuit (Log Alarm)
98 Compressor Sensor Short Circuit (Log Alarm)
99 USDA 1 Sensor Open Circuit (Check Alarm)
112 Zero Current Too High (Check Alarm)

No comments :